Thermal Fluid Heater

Typ WTOE

Our thermal fluid heater is a tubular heater constructed for the use of both organic and synthetic heat transfer fluids and for hot water. Its large combustion chamber provides best combustion results and guarantees thereby ideal emission rates.

Designs

The WTI thermal fluid heater is available for horizontal and vertical position.
IMG_9724
WTOE Umwaelzpumpe

Advantages

The advantage of the vertical position is that it provides a constant degassing of the heat transfer fluids in the pipe system. The pipe material - which is the heating surface - is therefore less worn out and is kept in better condition. The horizontal position of the WTI thermal fluid heater has the advantage that the combustor is easily accessible for maintenance purposes.
All our appliances comply with the DIN 4754 regulations of the German Institute for Standardization for steam boiler plants. They can be used in many different fields, not only because of their advantage of being in operation almost without pressure up to temperatures of 300°C and with only low overpressure up to 400°C. They can also operate during the vapour phase.
Minimaler Verschleiss, da auf die feuerfeste Ausmauerung verzichtet wird, indem die Brennkammer fast gänzlich durch die Rohrheizflächen gekühlt wird.
Wirkungsgrade über 92% werden durch den Einbau von Verbrennungsvorwärmern und Wärmetauschern erreicht. Sie dienen der Anhebung der Rücklauftemperatur bzw. der Beheizung von anlagenseitigen Wassersystemen.
Sicherheit: Die eingesetzten Regel-, Sicherheits- und Überwachungseinrichtungen sind baumustergeprüft und bewähren sich seit langer Zeit im Einsatz. Ein wesentliches Sicherungselement ist die durchflussabhängige Strömungssicherung, die ein Unterschreiten der mindest notwendigen Durchflussmenge durch den Kessel verhindert.
Nahezu drucklos: Werden Wärmeträgerölanlagen bei Temperaturen von 300°C betrieben, mit geringen Überdrücken sogar bis zu 400°C. Der Betrieb ist auch in der Dampfphase möglich.

Kesselfolgeschaltung: ab zwei Wärmeträgerölkessel erfolgt eine automatische Zu- und Abschaltung der Kessel je nach benötigter Leistung.

Dienstleistungen

  • Planung kompletter Heizanlagen bzw. Heizzentralen
  • Unterstützung bei den zuständigen Behörden
  • Kesselservice, Brennerservice, Emissionsmessungen

Montage

Wärmeträgerölanlagen werden auf Wunsch anschlussfertig, z.B. in einem Normcontainer oder auf gemeinsamen Grundrahmen zum sofortigen Aufstellen am Montageort vorgefertigt, geliefert. Dieses Konzept offeriert den flexiblen und raschen Einsatz vor Ort und reduziert die baulichen Vorarbeiten für den Kunden auf ein Minimum.
20210217_120901
IMG_2112
WTOE mit DG
WTOE mit AGWT
WTOE mit AGWT_Schnitt
RIMG0016
IMGP2758
IMGP2755
IMGP2754
IMGP2753
IMGP2752
IMGP2751
IMGP2745
IMGP2557
IMGP2556
IMGP2555
IMGP2554
IMGP2553
IMGP2552
IMGP2551
20201104_154724
20201104_141354
20170503_132545
201509 Ried W+ñrmeversorgung Fischer 2353
201509 Ried W+ñrmeversorgung Fischer 2339
201509 Ried Waermeversorgung Fischer 2337
201509 Ried W+ñrmeversorgung Fischer 2332
201509 Ried W+ñrmeversorgung Fischer 2325

WTOE - Hot water boiler

Our hot water boiler can be applied in the same fields as the WTI thermal fluid heater.

Applications

  • All forms of appliances
  • Containers
  • Presses
  • Steam Generators
  • Autoclaves
  • Machines
  • Buildings
The thermal fluid heater can be either fuelled directly by the use of light fuel oil, medium fuel oil, heavy fuel oil, scrap oil, solid fuels like coal, biomass - wood, sawdust and all sorts of gas - and electrical resistance heating or indirectly by liquids, waste gas, waste heat and steam. WTI has solutions for all these forms of heating. The use of heat transfer fluids guarantees a long durability of the plant. With thermal fluid plants the problem of corrosion is non-existent. Because of the use of oil, the inside can not corrode and the use of different fuels makes sure that the temperature on the outside is never below dew-point. As the combustor is cooled by the tubular heating surface, fireproof coating is not necessary. This results in only minimal wear of the material. An efficiency of over 90% is achieved by the use of combustion air pre-heaters and heat exchangers in order to raise the return-flow temperature or to heat plant-related water systems. All control and safety devices comply with the regulations of the responsible classification society and they have been in use successfully over the last years. One of the most important safety devices is a flow safety device which makes sure that the circulation quantity of the heat transfer fluid in the boiler is never below the required minimum. Thermal fluid plants can be delivered ready for installation, e.g. in a standard container or on a common frame so that the plants can be instantly installed at the respective place. This means for our customers: flexible and quick appliance of the plants with almost no preparations for the installation.